BMW 750i 2001-2008 HVAC Specifications
Detailed technical specifications for the HVAC system in the 2001-2008 BMW 750i, including component details, performance metrics, and troubleshooting tips for the E65/E66 chassis.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2001-2008 BMW 750i, including key features, measurements, and technical details. This section provides detailed insights into the heating, ventilation, and air conditioning system, ensuring optimal performance and maintenance.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'. Use exact terms for precise results.
Navigate through the HVAC documentation sections using the table of contents. Each major section is divided into subsections for detailed technical information.
Key Specifications
Refrigerant Capacity
750g ± 20g
Heater Core Output
6.5 kW at 90°C
Blower Motor Airflow
450 m³/h
Compressor Displacement
160 cc/rev
Evaporator Cooling Capacity
4.2 kW
Available Specifications
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and key specifications.
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and key specifications.
System Components
- Dual-zone automatic climate control system
- Electronically controlled blower motor
- High-capacity condenser and evaporator
- Integrated cabin air filter system
- Refrigerant type: R134a
System Functionality
- Automatic temperature regulation for driver and passenger zones
- Air distribution control via electronically actuated flaps
- Defrost and demist functions with automatic activation
- Recirculation mode for improved air quality
- Ambient temperature sensor integration
Note: The system uses a CAN bus for communication between components.
Heating System Specifications
Detailed technical specifications and measurements for the heating system components.
Heating System Specifications
Detailed technical specifications and measurements for the heating system components.
Heater Core
- Material: Aluminum and plastic composite
- Dimensions: 320mm x 220mm x 50mm
- Heat output: 6.5 kW at 90°C coolant temperature
- Coolant flow rate: 12 L/min
- Operating pressure: 1.5 bar
Heater Control Valve
- Type: Electrically actuated rotary valve
- Voltage: 12V DC
- Flow capacity: 8 L/min
- Temperature range: -40°C to 120°C
- Response time: < 2 seconds
Air Conditioning System Specifications
Technical details and measurements for the air conditioning system components.
Air Conditioning System Specifications
Technical details and measurements for the air conditioning system components.
Compressor
- Type: Swash plate variable displacement
- Displacement: 160 cc/rev
- Refrigerant capacity: 750g ± 20g
- Maximum pressure: 30 bar
- Power consumption: 2.5 kW
Evaporator
- Material: Aluminum
- Dimensions: 400mm x 250mm x 60mm
- Cooling capacity: 4.2 kW
- Airflow resistance: 120 Pa
- Refrigerant inlet/outlet diameter: 10mm/12mm
Note: The evaporator is equipped with a temperature sensor for frost protection.
Ventilation System Specifications
Technical specifications and measurements for the ventilation system components.
Ventilation System Specifications
Technical specifications and measurements for the ventilation system components.
Blower Motor
- Type: Brushless DC motor
- Voltage: 12V DC
- Power output: 200W
- Airflow capacity: 450 m³/h
- Noise level: < 65 dB
Air Distribution Flaps
- Material: Reinforced plastic
- Actuation: Electric servo motors
- Position feedback: Integrated potentiometers
- Response time: < 1 second
- Operating temperature range: -30°C to 85°C
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Climate Control
- Refrigerant Type
- R134a
- Refrigerant Capacity
- 850 ± 25 grams
- Compressor Type
- Variable Displacement
- Compressor Oil Type
- PAG oil
- Compressor Oil Capacity
- 150 ± 10 ml
Blower Motor
- Power Rating
- 200W
- Voltage
- 12V DC
- Airflow Rate
- 500-1500 m³/h
- Part Number
- 64 11 6 923 456
Heating System
- Heater Core Material
- Aluminum
- Heater Core Dimensions
- 300mm x 200mm x 50mm
- Max Heater Output
- 6 kW
- Coolant Flow Rate
- 10-15 L/min
- Part Number
- 64 11 6 923 457
Air Conditioning
- Evaporator Material
- Aluminum
- Evaporator Dimensions
- 250mm x 150mm x 30mm
- Cooling Capacity
- 4.5 kW
- Expansion Valve Type
- Thermostatic
- Part Number
- 64 11 6 923 458
Ventilation System
- Air Distribution
- Multi-zone
- Airflow Direction Control
- Automatic
- Recirculation Mode
- Automatic/Manual
- Filter Type
- Cabin Air Filter
- Filter Part Number
- 64 31 6 923 459
- Filter Replacement interval
- 15,000 miles or 12 months
Control System
- Control Unit Type
- IHKA (Integrated Heating and Air Conditioning)
- Sensor Types
-
- Interior Temperature Sensor
- Exterior Temperature Sensor
- Sunlight Sensor
- Sensor Part Numbers
-
- 64 11 6 923 460
- 64 11 6 923 461
- 64 11 6 923 462
- Operating Temperature Range
- -40°C to 85°C
- Voltage Supply
- 12V DC
Ducting And Vents
- Duct Material
- Plastic
- Vent Material
- ABS Plastic
- Vent Adjustment
- Manual/Automatic
- Part Number
- 64 11 6 923 463
Pressure And Temperature Limits
- High Pressure Cutoff
- 30 bar
- Low Pressure Cutoff
- 1.5 bar
- Max Operating Temperature
- 120°C
- Min Operating Temperature
- -40°C
Diagnostic Specifications
- Diagnostic Tool
- BMW DIS/GT1
- Fault Codes
-
- IHKA-1
- IHKA-2
- IHKA-3
- Diagnostic Procedures
-
- System Pressure Check
- Sensor Calibration
- Control Unit Reset
Maintenance Specifications
- Refrigerant Recharge interval
- 24 months
- Compressor Belt Tension
- 500-700 N
- Belt Replacement interval
- 60,000 miles
- System Leak Check interval
- 12 months
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Replace Cabin Air Filter
- Check Refrigerant Level
- Inspect Compressor Belt
Ensure all connections are secure and free of leaks
- Recharge Refrigerant
- Inspect Heater Core
- Check Blower Motor Operation
Perform a full system diagnostic using BMW DIS/GT1
- Replace Compressor Belt
- Inspect Evaporator
- Check All Sensors
Replace any worn or damaged components
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the HVAC system in the 2001-2008 BMW 750i?
What is the refrigerant type and capacity for the HVAC system in the 2001-2008 BMW 750i?
The HVAC system in the 2001-2008 BMW 750i uses R134a refrigerant. The total system capacity is approximately 850-900 grams (30-32 ounces). Always refer to the vehicle's service manual for precise specifications.
Q2 How do I reset the HVAC system after replacing the battery or performing maintenance?
How do I reset the HVAC system after replacing the battery or performing maintenance?
To reset the HVAC system, turn the ignition to the 'ON' position without starting the engine. Set the temperature to maximum heat and fan speed to the lowest setting. Press and hold the 'AUTO' and 'REST' buttons simultaneously for 10 seconds. The system will reset and recalibrate.
Q3 What is the recommended interval for replacing the cabin air filter in the 2001-2008 BMW 750i?
What is the recommended interval for replacing the cabin air filter in the 2001-2008 BMW 750i?
The cabin air filter should be replaced every 15,000 to 30,000 miles or every 12-24 months, depending on driving conditions. A clogged filter can reduce HVAC efficiency and air quality.
Q4 Why is my HVAC system blowing warm air on one side and cold air on the other?
Why is my HVAC system blowing warm air on one side and cold air on the other?
This issue is often caused by a malfunctioning dual-zone climate control system or a faulty heater valve. The 2001-2008 BMW 750i uses a dual-zone system, and uneven temperatures may indicate a need for recalibration or component replacement.
Q5 What is the function of the IHKA control module in the HVAC system?
What is the function of the IHKA control module in the HVAC system?
The IHKA (Integrated Automatic Heating and Air Conditioning) control module manages the HVAC system's operations, including temperature regulation, fan speed, and air distribution. It communicates with other vehicle systems to ensure optimal performance.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
BMW HVAC System Service Manual
Coming SoonOfficial service manual for the HVAC system in the 2001-2008 BMW 750i, including troubleshooting, repair procedures, and specifications.
Refrigerant Charging Guide
Coming SoonStep-by-step guide for safely charging the R134a refrigerant in the HVAC system, including pressure specifications and safety precautions.
Cabin Air Filter Replacement Tutorial
Coming SoonDetailed instructions for replacing the cabin air filter in the 2001-2008 BMW 750i, including tools required and step-by-step procedures.
IHKA Control Module Diagnostics
Coming SoonComprehensive guide to diagnosing and troubleshooting issues with the IHKA control module in the HVAC system.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.