Refrigerant Capacity
18.5 oz (525 g)
Heater Output
5.5 kW at 194°F (90°C)
Cooling Capacity
12,000 BTU/h (3.5 kW)
Airflow Capacity
400 to 600 CFM
Auxiliary Heater Output
1.5 kW
Available Specifications
Climate Control System
Details about the automatic climate control system, including its components and functionality.
Climate Control System
Details about the automatic climate control system, including its components and functionality.
Automatic Temperature Control
- Dual-zone automatic climate control system
- Temperature range: 60°F to 84°F (15.5°C to 28.9°C)
- Precision control with 0.5°F (0.3°C) increments
- Integrated humidity and air quality sensors
Air Distribution System
- Multi-level air vents with adjustable flow direction
- Airflow capacity: 400 to 600 cubic feet per minute (CFM)
- Automatic recirculation mode for improved air quality
- Dual blower motors for independent zone control
Note: The air distribution system is designed to minimize noise while maximizing efficiency.
Heating System
Technical specifications and features of the heating system, including performance metrics.
Heating System
Technical specifications and features of the heating system, including performance metrics.
Heater Core
- High-efficiency aluminum heater core
- Heat output: 5.5 kW at 194°F (90°C) coolant temperature
- Rapid warm-up time: 3-5 minutes in cold conditions
- Integrated thermostat for precise temperature regulation
Auxiliary Heating
- Electric auxiliary heater with 1.5 kW output
- Activation temperature: below 41°F (5°C)
- Energy-efficient operation with minimal battery drain
- Automatic deactivation above 50°F (10°C)
Note: The auxiliary heating system is ideal for cold climates and improves cabin comfort during engine warm-up.
Air Conditioning System
Detailed information about the air conditioning system, including refrigerant specifications and cooling performance.
Air Conditioning System
Detailed information about the air conditioning system, including refrigerant specifications and cooling performance.
Refrigerant System
- Refrigerant type: R-1234yf
- Refrigerant capacity: 18.5 oz (525 g)
- Operating pressure: 150-300 psi (10.3-20.7 bar)
- Environmentally friendly with low global warming potential (GWP)
Cooling Performance
- Maximum cooling capacity: 12,000 BTU/h (3.5 kW)
- Cabin temperature reduction: 20°F (11°C) in 5 minutes
- Variable compressor with electronic control
- Energy-saving eco mode for reduced fuel consumption
Note: The air conditioning system is optimized for both performance and energy efficiency.
Ventilation and Air Quality
Features and specifications related to cabin ventilation and air quality management.
Ventilation and Air Quality
Features and specifications related to cabin ventilation and air quality management.
Air Filtration System
- High-efficiency particulate air (HEPA) filter
- Filter replacement interval: 15,000 miles (24,000 km)
- Removes 99.97% of airborne particles
- Activated carbon layer for odor reduction
Ventilation Modes
- Four ventilation modes: Auto, Max, Eco, and Manual
- Adjustable fan speed: 1 to 7 levels
- Defrost mode with rapid windshield clearing
- Footwell and upper body ventilation options
Note: The ventilation system ensures consistent airflow distribution for enhanced comfort.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Climate Control
- Refrigerant Type
- R-1234yf
- Refrigerant Capacity
- 500 ± 20 g
- Compressor Type
- Variable Displacement
- Blower Motor Type
- Electronically Controlled
- Airflow Capacity
- Up to 1000 m³/h
Temperature Control
- Temperature Range
- 16°C to 32°C
- Temperature Resolution
- 0.5°C
- Dual Zone Control
- true
- Rear Seat Control
- false
- Sensor Accuracy
- ±0.5°C
Air Distribution
- Vent Modes
-
- Face
- Foot
- Defrost
- Auto
- Airflow Direction Adjustment
- Manual and Automatic
- Rear Vent Airflow
- Fixed
- Defrost Time
- 3-5 minutes at full power
Filtration System
- Filter Type
- Cabin Microfilter with Activated Carbon
- Filter Part Number
- 64 31 9 388 123
- Filter Replacement interval
- Every 15,000 miles or 12 months
- Filter Efficiency
- 99% for particles > 0.3 microns
Compressor Specifications
- Compressor Part Number
- 64 51 9 388 456
- Displacement
- 120 cc
- Maximum Pressure
- 30 bar
- Oil Type
- PAG 46
- Oil Capacity
- 150 ± 10 ml
Condenser Specifications
- Condenser Part Number
- 64 51 9 388 789
- Material
- Aluminum
- Core Thickness
- 16 mm
- Pressure Rating
- 35 bar
- Cooling Capacity
- 8 kW
Evaporator Specifications
- Evaporator Part Number
- 64 51 9 388 321
- Material
- Aluminum
- Core Thickness
- 12 mm
- Cooling Capacity
- 5 kW
- Pressure Rating
- 25 bar
Blower Motor Specifications
- Blower Motor Part Number
- 64 11 9 388 654
- Power Rating
- 200 W
- Voltage
- 12 V
- Speed Range
- 0 to 100% in 10% increments
- Noise Level
- < 50 dB at max speed
Diagnostic Specifications
- Diagnostic Port
- OBD-II
- Fault Codes
-
- P0532
- P0533
- P0534
- P0535
- Self Diagnosis
- true
- Diagnostic interval
- Every ignition cycle
- Error Tolerance
- ±2%
Operational Limits
- Maximum Ambient Temperature
- 50°C
- Minimum Ambient Temperature
- -30°C
- Maximum System Pressure
- 35 bar
- Minimum System Pressure
- 1 bar
- Maximum Compressor Speed
- 6000 rpm
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Replace cabin microfilter
- Inspect refrigerant level
- Check compressor belt tension
Service intervals may vary based on driving conditions
- Inspect condenser for debris
- Check blower motor operation
- Verify temperature sensor calibration
Perform a full system diagnostic if issues are detected
- Replace refrigerant
- Inspect evaporator for leaks
- Check all electrical connections
Use only BMW-approved refrigerant and lubricants
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2017-Present BMW 440i HVAC system?
What is the refrigerant type and capacity for the 2017-Present BMW 440i HVAC system?
The HVAC system in the 2017-Present BMW 440i uses R-1234yf refrigerant. The total system capacity is approximately 525 grams (18.5 ounces). Always ensure the refrigerant is handled by a certified technician to avoid system damage or safety hazards.
Q2 What is the recommended cabin air filter replacement interval for the BMW 440i?
What is the recommended cabin air filter replacement interval for the BMW 440i?
The cabin air filter should be replaced every 15,000 to 20,000 miles or at least once a year, depending on driving conditions. A clogged filter can reduce HVAC efficiency and air quality.
Q3 How does the automatic climate control system work in the BMW 440i?
How does the automatic climate control system work in the BMW 440i?
The automatic climate control system uses sensors to monitor cabin temperature, sunlight intensity, and humidity. It adjusts fan speed, air distribution, and temperature settings automatically to maintain the desired comfort level. The system also includes a microfilter to improve air quality.
Q4 What are the common symptoms of a failing HVAC blower motor in the BMW 440i?
What are the common symptoms of a failing HVAC blower motor in the BMW 440i?
Common symptoms include unusual noises (whirring or grinding), reduced airflow, or complete failure of the blower motor. If these issues occur, the blower motor or its resistor may need replacement. Always consult a certified technician for diagnosis and repair.
Q5 Can I retrofit the HVAC system in my BMW 440i to support newer refrigerants?
Can I retrofit the HVAC system in my BMW 440i to support newer refrigerants?
No, retrofitting the HVAC system to support different refrigerants is not recommended. The system is specifically designed for R-1234yf, and using incompatible refrigerants can damage components, void warranties, and pose safety risks.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
BMW HVAC System Maintenance Guide
Coming SoonA detailed guide on maintaining the HVAC system, including filter replacement, refrigerant handling, and troubleshooting tips.
BMW 440i Owner's Manual
Coming SoonThe official owner's manual for the BMW 440i, including HVAC system operation, settings, and maintenance recommendations.
BMW Genuine Parts Catalog
Coming SoonAccess the official BMW parts catalog to find genuine HVAC components, including filters, blower motors, and refrigerant.
BMW Service Bulletins for HVAC Systems
Coming SoonA collection of service bulletins related to HVAC system updates, recalls, and common issues for the BMW 440i.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.