BMW 340i 2005-2011 HVAC Specifications
Detailed technical specifications for the HVAC system in the 2005-2011 BMW 340I, including component details, performance metrics, and troubleshooting tips.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2005-2011 BMW 340I, including key features, measurements, and technical details.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'.
Navigate through the HVAC documentation sections using the table of contents or by scrolling through the document. Each major section is labeled with a title and contains subsections for detailed information.
Key Specifications
Refrigerant Capacity
600 ± 20 g
Blower Motor Power
200 W
Maximum Heating Output
6 kW
Maximum Cooling Capacity
4.5 kW
Operating Pressure (High Side)
15-20 bar
Available Specifications
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and key specifications.
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and key specifications.
System Components
- Dual-zone automatic climate control system
- Electronically controlled blower motor
- High-performance condenser and evaporator
- Integrated cabin air filter system
- Refrigerant type: R134a
System Functionality
- Automatic temperature regulation with dual-zone control
- Adjustable airflow distribution (face, foot, windshield)
- Defrost and demist functions with automatic activation
- Energy-saving mode for reduced power consumption
- Integrated air quality sensor for automatic recirculation
Note: The dual-zone system allows the driver and front passenger to set individual temperature preferences.
Refrigerant System Specifications
This section details the refrigerant system, including capacity, pressure, and maintenance requirements.
Refrigerant System Specifications
This section details the refrigerant system, including capacity, pressure, and maintenance requirements.
Refrigerant Capacity
- Total refrigerant capacity: 600 ± 20 g
- Refrigerant type: R134a
- Operating pressure: High side - 15-20 bar, Low side - 2-3 bar
- Refrigerant oil capacity: 120 ± 10 ml
- Recommended service interval: Every 2 years or 30,000 miles
Refrigerant System Components
- High-efficiency condenser with 12 rows
- Aluminum evaporator with 16 rows
- Thermostatic expansion valve (TXV) for precise flow control
- High-pressure switch with a cutoff at 32 bar
- Low-pressure switch with a cutoff at 1.5 bar
Note: Ensure proper refrigerant levels to avoid system inefficiency or damage.
Blower Motor and Air Distribution
This section covers the blower motor, air distribution system, and related controls.
Blower Motor and Air Distribution
This section covers the blower motor, air distribution system, and related controls.
Blower Motor Specifications
- Blower motor power rating: 200 W
- Maximum airflow: 450 m³/h
- 12-speed electronically controlled fan
- Noise level at maximum speed: 65 dB
- Service life: 10 years or 150,000 miles
Air Distribution System
- Adjustable vents with 4-way directional control
- Automatic air recirculation based on cabin air quality
- Dual-zone airflow control with independent settings
- Defrost vents with optimized airflow for windshield clearing
- Footwell vents with adjustable temperature settings
Note: The air distribution system ensures optimal comfort for all occupants.
Heating and Cooling Performance
This section provides details on the heating and cooling performance of the HVAC system.
Heating and Cooling Performance
This section provides details on the heating and cooling performance of the HVAC system.
Heating Performance
- Maximum heating output: 6 kW
- Heating element type: PTC (Positive Temperature Coefficient)
- Time to reach maximum temperature: 5 minutes
- Temperature range: 16°C to 32°C
- Integrated heat exchanger for efficient operation
Cooling Performance
- Maximum cooling capacity: 4.5 kW
- Evaporator temperature range: 2°C to 10°C
- Time to reach minimum temperature: 7 minutes
- Temperature range: 16°C to 32°C
- Energy-efficient compressor with variable displacement
Note: The cooling system is designed for rapid temperature reduction and energy efficiency.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Climate Control
- Refrigerant Type
- R134a
- Refrigerant Capacity
- 600 ± 25 grams
- Compressor Type
- Variable Displacement
- Compressor Oil Type
- PAG 46
- Compressor Oil Capacity
- 150 ± 10 ml
Blower Motor
- Power Rating
- 200W
- Voltage
- 12V DC
- Airflow Rate
- Max 450 m³/h
- Part Number
- 64116920417
- Operational Temperature Range
- -40°C to 85°C
Heating System
- Heater Core Material
- Aluminum
- Heater Core Flow Rate
- 5.5 ± 0.5 liters/min
- Heater Core Part Number
- 64116920418
- Max Heater Output
- 6.5 kW
- Coolant Temperature Range
- 80°C to 105°C
Air Conditioning
- Evaporator Material
- Aluminum
- Evaporator Part Number
- 64116920419
- Evaporator Temperature Range
- 2°C to 10°C
- Condenser Material
- Aluminum
- Condenser Part Number
- 64116920420
- Condenser Pressure Range
- 10 to 30 bar
Air Distribution
- Vent Types
-
- Dashboard Vents
- Floor Vents
- Defrost Vents
- Vent Material
- ABS Plastic
- Vent Actuator Type
- Stepper Motor
- Vent Actuator Part Number
- 64116920421
- Airflow Direction Control
- Automatic and Manual
Filters
- Cabin Air Filter Type
- Combination Filter (Particle and Activated Carbon)
- Cabin Air Filter Part Number
- 64116920422
- Filter Replacement interval
- 15,000 miles or 12 months
- Filter Efficiency
- Particle Filtration: 95%, Odor Reduction: 85%
Control Unit
- Control Unit Type
- IHKA (Integrated Heating and Air Conditioning)
- Control Unit Part Number
- 64116920423
- Operational Voltage
- 12V DC
- Temperature Sensor Range
- -40°C to 85°C
- Humidity Sensor Range
- 5% to 95% RH
Sensors
- interior Temperature Sensor
- Type: NTC ThermistorPart Number: 64116920424Range: -40°C to 85°CAccuracy: ±0.5°C
- Exterior Temperature Sensor
- Type: NTC ThermistorPart Number: 64116920425Range: -40°C to 85°CAccuracy: ±1°C
- Sunlight Sensor
- Type: PhotodiodePart Number: 64116920426Range: 0 to 100,000 LuxAccuracy: ±5%
Diagnostics
- Diagnostic interface
- OBD-II
- Fault Codes
-
- P0532
- P0533
- P0534
- P0535
- Diagnostic Tool
- BMW ISTA/D
- Self Diagnosis Capability
- Yes
- Error Code Storage
- Up to 20 codes
Safety
- High Pressure Cutoff
- 30 bar
- Low Pressure Cutoff
- 2 bar
- Overheat Protection
- 105°C
- Electrical Fuse Rating
- 20A
- Emergency Shutoff
- Automatic in case of system failure
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Inspect and replace cabin air filter
- Check refrigerant level and pressure
- Inspect blower motor and vents
- Test HVAC control unit functionality
Ensure all connections are secure and free of debris
- Inspect and clean evaporator and condenser
- Check heater core for leaks
- Inspect all sensors and actuators
- Perform system pressure test
Use only BMW-approved refrigerant and lubricants
- Replace refrigerant and oil
- Inspect and replace compressor if necessary
- Check and recalibrate control unit
- Perform full system diagnostic
Ensure all components meet BMW specifications
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2005-2011 BMW 340i HVAC system?
What is the refrigerant type and capacity for the 2005-2011 BMW 340i HVAC system?
The HVAC system in the 2005-2011 BMW 340i uses R134a refrigerant. The total system capacity is approximately 700-750 grams (24.7-26.5 ounces). Always refer to the vehicle's service manual for exact specifications.
Q2 How do I reset the HVAC system after replacing components?
How do I reset the HVAC system after replacing components?
After replacing HVAC components, a system reset is required. Use a BMW-specific diagnostic tool (e.g., ISTA/D or INPA) to reset the IHKA (Integrated Automatic Heating and Air Conditioning) control module. This ensures proper calibration and functionality.
Q3 What is the recommended interval for cabin air filter replacement?
What is the recommended interval for cabin air filter replacement?
The cabin air filter should be replaced every 15,000-20,000 miles or annually, whichever comes first. In dusty or polluted environments, more frequent replacement may be necessary.
Q4 How do I diagnose a weak airflow from the HVAC system?
How do I diagnose a weak airflow from the HVAC system?
Weak airflow can result from a clogged cabin air filter, a malfunctioning blower motor, or obstructed air ducts. Inspect the cabin air filter first, then test the blower motor and check for debris in the ducts. Use a diagnostic tool to verify the IHKA module's operation.
Q5 What are the common symptoms of a failing HVAC compressor?
What are the common symptoms of a failing HVAC compressor?
Common symptoms include insufficient cooling, unusual noises (e.g., grinding or squealing), refrigerant leaks, and the A/C clutch not engaging. If the compressor fails, replace it with a genuine BMW part to ensure compatibility and performance.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
BMW HVAC System Overview
Coming SoonA detailed guide to the HVAC system in the 2005-2011 BMW 340i, including component locations and functions.
Refrigerant Handling and Safety
Coming SoonLearn about proper refrigerant handling, safety precautions, and environmental regulations for R134a.
IHKA Control Module Reset Procedure
Coming SoonStep-by-step instructions for resetting the IHKA control module using BMW diagnostic tools.
Cabin Air Filter Replacement Guide
Coming SoonA visual guide to replacing the cabin air filter in the 2005-2011 BMW 340i.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.